ī i - stable alarm relay Prevents increased current draw in case of an alarm.

A residual current of 10mA for example may damage a 200Ah battery if the system is left in discharged state during more than 8 days. The battery will be damaged if the remaining capa city reserve is drawn from the battery. After shutdown due to low cell voltage, the capacity reserve of a Li -ion battery is approximately 1Ah per 100Ah battery capacity. Very low current draw from the battery C urrent consumption: 0,7Ah per month (1mA) and 0,6 Ah per mont h (0,8 mA) 24V Especially Li -ion batteries have virtually no capacity left when discharged until low voltage shutdown. The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted.

Connection to the SmartShunt is made via a VE.Direct cable. The SmartShunt connects via Bluetooth to the VictronConnect App on your phone (or tablet) and you can conveniently read out all monitored battery parameters, like state of charge, time to go, historical information and much more.Īlternatively the SmartShunt can be connected and be read by a GX device. The SmartShunt is an all in one battery monitor, only without a display.